1, product description
Introducing the TYJX series frequency conversion drive high-efficiency rare earth permanent magnet synchronous motor, a marvel of modern engineering by Taizhou Taicheng Electrical Equipment Co., Ltd. This fully enclosed, air-cooled motor is meticulously crafted for the fan industry, delivering unparalleled performance. It boasts an efficiency index that meets the stringent GB30253-2013 standards, surpassing the Class 1 energy efficiency benchmark, positioning it at the forefront of similar products. Harnessing the superior magnetic capabilities of rare earth materials, this motor eliminates the need for additional energy post-magnetization, creating a powerful permanent magnetic field that replaces traditional electric excitation. The result? A motor that's not only extraordinarily efficient but also elegantly simple in structure, operationally reliable, and compact in both size and weight. These advanced features offer swift dynamic response and can be customized to meet your specific operational demands. Through an innovative fusion of permanent magnet technology, cutting-edge electronics, and microcomputer controls, we elevate motor and drive system performance, ushering in a new era of intelligent motor capabilities. Perfectly suited for a variety of fan applications, this motor is a testament to technological excellence.
Our permanent magnet synchronous motor is a testament to engineering brilliance, characterized by its novel design, compact structure, and superior efficiency. Enjoy the benefits of a high power factor, impressive starting torque, energy-saving technology, and whisper-quiet operation. Experience minimal vibrations, a hallmark of safety and reliability, and exceptional energy efficiency.
2, Features
High efficiency:This remarkable motor surpasses the national first-class energy efficiency standard, proudly conforming to the prestigious IE5 energy efficiency standard, representing the pinnacle of energy-saving technology.
High power factor:With a rotor devoid of induction current excitation and a stator presenting a resistive load, the motor flaunts a power factor exceeding 0.95, eliminating the need for reactive power compensation.
High return on electricity saving:Opt for this motor over traditional asynchronous motors and witness a comprehensive power saving of 15% to 30%, depending on load conditions.
Small current:Experience over 20% reduction in current compared to 3-phase asynchronous motors, eradicating the necessity for reactive power compensation. This advantage translates to significant savings in cable and transformer investments when planning store layouts.
Low temperature rise:With no copper loss in the rotor winding and the absence of reactive current in the stator winding, this motor maintains a temperature rise over 20k lower than its asynchronous counterparts.
Good control performance:The permanent magnet synchronous motor offers effortless control, eliminating speed slip, providing excellent dynamic response, and ensuring precise speed control, particularly beneficial for high-speed applications.
3, Products Parameter
motor model |
power |
Voltage |
series |
Rotating speed |
Insulation class |
factor |
degree of protection |
TYJX-90L |
1.1kW |
D220V\/50Hz |
16 |
500 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.75kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.75kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.4kW |
S380V\/50Hz |
16 |
720 |
f |
0.95 |
IP55 |
TYJX-90L |
0.75kW |
S380V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D110V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D220V\/50Hz |
16 |
450 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
1.1kW |
D220V\/50Hz |
16 |
1420 |
f |
0.95 |
IP55 |
TYJX-100L |
0.75kW |
D220V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
D220V\/50Hz |
20 |
520 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
D220V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
D220V\/50Hz |
20 |
460 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
D220V\/50Hz |
20 |
700 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
D220V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
3kW |
D220V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
S380V\/50Hz |
20 |
600 |
f |
0.95 |
IP55 |
TYJX-100L |
0.4kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-100L |
0.75kW |
S380V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
S380V\/50Hz |
20 |
520 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
S380V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
S380V\/50Hz |
20 |
460 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
S380V\/50Hz |
20 |
600 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
S380V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
3kW |
S380V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
S380V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
0.4kW |
S380V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-100L |
3kW |
D220V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
2.5kW |
S380V\/50Hz |
20 |
1000 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
S380V\/50Hz |
20 |
1000 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
S380V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-112M |
1.5kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-112M |
1.8kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
D220V\/50Hz |
20 |
550 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
D220V\/50Hz |
20 |
500 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
D220V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
S380V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
0.55kW |
D220V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
S380V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
1.8kW |
D220V\/50Hz |
20 |
|
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
D220V\/50Hz |
20 |
550 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
D220V\/50Hz |
20 |
500 |
f |
0.95 |
IP55 |
Principle of energy saving
1). Utilizing high-performance rare earth permanent magnets, the rotor of the synchronous motor generates a fixed magnetic field, powered by permanent magnets and current. The stator's rotating magnetic field propels the rotor magnetic field, achieving synchronization without the need for excitation current or winding, thus guaranteeing high energy efficiency.
2). In contrast, asynchronous motors rely on induced current generated by the stator's rotating magnetic field to produce electromagnetic torque, resulting in a rotor speed that must lag the synchronous speed.
3). With a power density approximately 30% higher than that of equivalent asynchronous motors, permanent magnet motors excel in efficiency. They are 1-2 frame sizes smaller than asynchronous motors of the same power, leading to reduced iron and mechanical losses due to their compact size.
4). The Permanent Magnet Synchronous Motor (PMSM) offers superior efficiency compared to asynchronous motors of identical power ratings, extending its high-efficiency performance over a broader operational range. When operating within 25%-100% of its rated speed, the PMSM consistently maintains a high-efficiency status. In contrast, the asynchronous motor experiences a significant efficiency decline when its speed falls below 70% of the rated speed.
5, Conditions of Use
1). Altitude: Must not exceed 1000 meters, ensuring optimal performance.
2). Ambient Temperature: Adaptable to seasonal variations, maintained between -15°C and 40°C for reliable operation.
3). Working Mode: Designed for continuous operation (S1), ensuring uninterrupted performance.
4). Rated Voltage: Available options are 200V/380V and 50Hz/60Hz, with a permissible voltage fluctuation range of ±10%.
5). Enclosure Protection Grade: Built to the IP55 standard, providing robust protection against dust and water ingress.
6). Cooling Method: Equipped with IC410 cooling technology to efficiently manage thermal regulation.