1,Product Description
The TYJX series frequency conversion drive high-efficiency rare earth permanent magnet synchronous motor is a state-of-the-art, fully enclosed air-cooled motor crafted by Taizhou Taicheng Electrical Equipment Co., Ltd., specifically for the diverse demands of the fan industry. This outstanding series reaches the GB30253-2013 permanent magnet synchronous motor energy efficiency limit value, surpassing Class 1 standards, and ranks among the elite in energy efficiency for similar products. Harnessing the superior magnetic properties of rare earth permanent materials, these motors do not require additional energy post-magnetization, establishing a robust permanent magnetic field that replaces traditional motor electric excitation fields. As a result, the rare earth permanent magnet motor boasts exceptional efficiency, a streamlined structure, dependable operation, compact size, and lightweight design. This innovative motor can deliver rapid response speeds and can be customized to meet specific operational requirements. The symbiotic integration of permanent magnet motor, cutting-edge electronic technology, and advanced microcomputer control elevates the performance of the motor and drive systems to unprecedented heights, enhancing the motor's intelligence and adaptability. Ideal for an array of fan applications, this motor sets a new benchmark in innovation and utility.
The permanent magnet synchronous motor stands out with its avant-garde design, compact architecture, and superior efficiency, offering a high power factor. It delivers excellent starting torque, conserves energy, operates with minimal noise and vibration, and ensures safe and reliable performance. This motor epitomizes high efficiency and energy conservation, making it an invaluable asset in modern applications.
2,Features
High Efficiency:Exceeding national first-class energy efficiency benchmarks, this motor attains the prestigious national standard IE5 energy efficiency level.
High Power Factor:With no induction current excitation in the permanent magnet motor rotor, the stator winding acts as a resistive load, achieving a power factor above 0.95, eliminating the need for reactive power compensation.
High Return on Electricity Saving:Depending on load conditions, when replacing asynchronous motors, the comprehensive power saving rate is an impressive 15%-30%.
Small Current:Compared with 3-phase asynchronous motors, the current is reduced by over 20%, negating the need for reactive power compensation. This feature significantly decreases investment in cables and transformers during store layout planning.
Low Temperature Rise:The absence of copper loss in the rotor winding and reactive current in the stator winding results in a temperature rise more than 20k lower than asynchronous motors.
Good Control Performance:Easily controllable, the permanent magnet synchronous motor boasts no speed slip, outstanding dynamic response performance, and precise speed control, offering remarkable advantages for high-speed requirement scenarios.
3,Products Parameter
motor model |
power |
Voltage |
series |
Rotating speed |
Insulation class |
factor |
degree of protection |
TYJX-90L |
1.1kW |
D220V\/50Hz |
16 |
500 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.75kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.75kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.4kW |
S380V\/50Hz |
16 |
720 |
f |
0.95 |
IP55 |
TYJX-90L |
0.75kW |
S380V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D110V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D220V\/50Hz |
16 |
450 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
1.1kW |
D220V\/50Hz |
16 |
1420 |
f |
0.95 |
IP55 |
TYJX-100L |
0.75kW |
D220V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
D220V\/50Hz |
20 |
520 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
D220V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
D220V\/50Hz |
20 |
460 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
D220V\/50Hz |
20 |
700 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
D220V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
3kW |
D220V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
S380V\/50Hz |
20 |
600 |
f |
0.95 |
IP55 |
TYJX-100L |
0.4kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-100L |
0.75kW |
S380V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
S380V\/50Hz |
20 |
520 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
S380V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
S380V\/50Hz |
20 |
460 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
S380V\/50Hz |
20 |
600 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
S380V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
3kW |
S380V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
S380V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
0.4kW |
S380V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-100L |
3kW |
D220V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
2.5kW |
S380V\/50Hz |
20 |
1000 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
S380V\/50Hz |
20 |
1000 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
S380V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-112M |
1.5kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-112M |
1.8kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
D220V\/50Hz |
20 |
550 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
D220V\/50Hz |
20 |
500 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
D220V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
S380V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
0.55kW |
D220V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
S380V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
1.8kW |
D220V\/50Hz |
20 |
|
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
D220V\/50Hz |
20 |
550 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
D220V\/50Hz |
20 |
500 |
f |
0.95 |
IP55 |
Principle of Energy Saving
1). The rotor of the permanent magnet synchronous motor employs high-performance rare earth permanent magnet materials to produce a steady magnetic field (generated by permanent magnets and current). The stator's rotating magnetic field drives the rotor's magnetic field, ensuring the rotor's speed matches the synchronous speed without requiring excitation current or winding, thus achieving superior energy efficiency.
2). Asynchronous motors generate induced current in the rotor through the stator's rotating magnetic field to produce electromagnetic torque. The rotor's magnetic field is indirectly generated, thus it must operate below synchronous speed.
3). The power density of permanent magnet motors is approximately 30% higher than that of asynchronous motors of equivalent power. For the same power output, permanent magnet motors are 1-2 frame sizes smaller than their asynchronous counterparts. This compact size translates to reduced iron loss and mechanical losses, enhancing overall efficiency and performance.
4). Experience unparalleled efficiency with our permanent magnet synchronous motor, surpassing the asynchronous motor of equivalent power. Not only does it boast superior efficiency, but its high-efficiency zone is also remarkably expansive. Operating within a speed range of 25%-100% of the rated speed, the permanent magnet synchronous motor consistently performs in the high-efficiency zone. In contrast, the asynchronous motor sees a significant efficiency decline when its speed range falls below 70% of the rated speed.
5, Conditions of Use
1). Altitude: Ensure it is utilized at altitudes not exceeding 1000m.
2). Ambient temperature: Adaptable with seasonal changes, but the temperature must stay within -15 degrees Celsius to 40 degrees Celsius.
3). Working mode: Designed for continuous working systems (S1) to ensure steady and reliable performance.
4). Rated voltage: Enjoy versatility with a rated voltage of 200V/380V, 50Hz/60Hz, and benefit from a permissible variation range of ±10%.
5). With a robust enclosure protection grade of IP55, our motor is built to withstand demanding conditions.
6). Efficiently cooled using the IC410 method, ensuring optimal performance under varied conditions.