Introducing the TYJX Series Frequency Conversion Drive: an avant-garde masterpiece of engineering, the high-efficiency rare earth permanent magnet synchronous motor. Exquisitely crafted and fully enclosed for optimal air cooling, this motor is tailor-made for the fan industry, setting new standards with an efficiency index that triumphs over the GB30253-2013 benchmark. Its energy efficiency level surpasses even Class 1, defining a new apex in excellence. Exploiting the superior magnetic prowess of rare earth elements, this motor eliminates the necessity for extra energy in magnetization, establishing an indomitable permanent magnetic field that supersedes conventional electric excitation. The outcome? A motor characterized by unrivaled efficiency, simplistic design, unwavering performance, and compact, lightweight form. The harmonious integration of permanent magnet technology with leading-edge electronic and microcomputer control propels motor and drive system performance to extraordinary echelons, signaling a new epoch of intelligence in motor technology. Its application is as versatile as it is extensive across a wide array of fan domains.
The Permanent Magnet Synchronous Motor distinguishes itself with a groundbreaking design and compact architecture. It promises exceptional efficiency and a preeminent power factor, delivering outstanding starting torque. Revel in substantial energy savings, diminished noise levels, minimal vibration, and a promise of safe, reliable operation, all while achieving extraordinary energy conservation.
2,Features
High Efficiency:Achieving a rated efficiency that surpasses the national first-class energy efficiency benchmark, our motors proudly reach the distinguished national standard IE5 energy efficiency level.
High Power Factor:By eradicating induction current excitation within the rotor, the stator winding presents a resistive load, ensuring a power factor exceeding 0.95, without the necessity for reactive power compensation.
High Return on Electricity Saving:Our motors, replacing their asynchronous counterparts, yield a comprehensive power saving rate ranging from 15% to 30% under varying load conditions.
Small Current:Our innovative design, compared to 3-phase asynchronous motors, reduces current by over 20%, eliminating the need for reactive power compensation. This optimizes store layout, ultimately leading to significant cost reductions on cables and transformers.
Low Temperature Rise:The elimination of copper loss in the rotor winding and reactive current in the stator winding culminates in a temperature rise reduction exceeding 20k when compared to asynchronous motors.
Good Control Performance:Our permanent magnet synchronous motors are engineered for facile control, devoid of speed slip, and exhibit exceptional dynamic response and precise speed control, rendering them ideal for high-speed applications.
3,Products Parameter
motor model |
power |
Voltage |
series |
Rotating speed |
Insulation class |
factor |
degree of protection |
TYJX-90L |
1.1kW |
D220V\/50Hz |
16 |
500 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.75kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.75kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.4kW |
S380V\/50Hz |
16 |
720 |
f |
0.95 |
IP55 |
TYJX-90L |
0.75kW |
S380V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D110V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D220V\/50Hz |
16 |
450 |
f |
0.95 |
IP55 |
TYJX-90L |
0.6kW |
D220V\/50Hz |
16 |
650 |
f |
0.95 |
IP55 |
TYJX-90L |
1.1kW |
D220V\/50Hz |
16 |
1420 |
f |
0.95 |
IP55 |
TYJX-100L |
0.75kW |
D220V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
D220V\/50Hz |
20 |
520 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
D220V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
D220V\/50Hz |
20 |
460 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
D220V\/50Hz |
20 |
700 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
D220V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
3kW |
D220V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
S380V\/50Hz |
20 |
600 |
f |
0.95 |
IP55 |
TYJX-100L |
0.4kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-100L |
0.75kW |
S380V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
S380V\/50Hz |
20 |
520 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
S380V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
S380V\/50Hz |
20 |
460 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
S380V\/50Hz |
20 |
600 |
f |
0.95 |
IP55 |
TYJX-100L |
2.2kW |
S380V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
3kW |
S380V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
1.1kW |
S380V\/50Hz |
20 |
530 |
f |
0.95 |
IP55 |
TYJX-100L |
0.4kW |
S380V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-100L |
3kW |
D220V\/50Hz |
20 |
1440 |
f |
0.95 |
IP55 |
TYJX-100L |
2.5kW |
S380V\/50Hz |
20 |
1000 |
f |
0.95 |
IP55 |
TYJX-100L |
1.5kW |
S380V\/50Hz |
20 |
1000 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
S380V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-112M |
1.5kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-112M |
1.8kW |
D220V\/50Hz |
20 |
720 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
D220V\/50Hz |
20 |
550 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
D220V\/50Hz |
20 |
500 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
D220V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
S380V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
0.55kW |
D220V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
S380V\/50Hz |
20 |
450 |
f |
0.95 |
IP55 |
TYJX-112M |
1.8kW |
D220V\/50Hz |
20 |
|
f |
0.95 |
IP55 |
TYJX-112M |
0.75kW |
D220V\/50Hz |
20 |
550 |
f |
0.95 |
IP55 |
TYJX-112M |
1.1kW |
D220V\/50Hz |
20 |
500 |
f |
0.95 |
IP55 |
Principle of Energy Saving
1). Our motors ingeniously utilize high-performance rare earth permanent magnet materials in the rotor to establish a fixed magnetic field. This field is birthed through the interaction of permanent magnets and current. With the stator's rotating magnetic field leading the rotor, synchronization ensues without the need for excitation current or winding, achieving unmatched energy efficiency.
2). Conversely, asynchronous motors depend upon induced current in the rotor, propelled by the stator's rotating magnetic field, to generate electromagnetic torque. This configuration inherently results in the rotor's speed being inferior to synchronous speed.
3). Permanent magnet motors exhibit a 30% higher power density compared to asynchronous motors of equivalent power. Their more compact size, being 1-2 frame sizes smaller, translates to reduced iron and mechanical loss, thanks to their diminutive dimensions.
4). The permanent magnet synchronous motor (PMSM) surpasses the asynchronous motor in efficiency, offering exemplary performance for an equivalent power level. Notably, its high-efficiency zone is substantially broader. When functioning within 25%-100% of its rated speed, the PMSM consistently operates within the high-efficiency zone. In contrast, the asynchronous motor's efficiency markedly declines when its speed falls below 70% of the rated speed.
5. Conditions of Use
1). Altitude: Maxi mal operational elevation is 1000 meters above sea level, ensuring optimal motor performance at standard altitudes.
2). Ambient temperature: Adapts to seasonal changes with proficiency, maintaining operational integrity between -15°C and 40°C.
3). Working Mode: Expertly crafted for non-stop, continuous duty operation (S1), providing unparalleled reliability and performance.
4). Rated Voltage: Versatile with options of 200V/380V and frequency compatibility of 50Hz/60Hz. Voltage variance allowance stands at ±10% for stability and adaptability.
5). Enclosure Protection: Boasting an impressive IP55 protection grade, this motor offers superior safeguarding against adverse environmental factors.
6). Cooling Method: Integrated with an advanced IC410 cooling system, enhancing performance efficiency and extending motor service life.